LT THERMO
Electric heating rod with thermostat for automatic control of radiators
Function:
- Comfort = thermostat maintains the temperature of the liquid in the radiator according to the user's settings (from 40 ° C to 65 ° C)
- Boost = fast heating to maximum for 2 hours, then returns to Comfort mode
- Timer = activation of Boost mode for 2 hours, then Comfort for 10 or 22 hours, the cycle is constantly repeated
- Antifreeze = standby mode monitors the measured temperature, if it drops below 10 ° C, heating is activated to prevent the liquid inside the radiator from freezing
Technical parameters
- Protection class: I and II
- Operating voltage: 230 V / 50 Hz
- Temperature setting: Digital
- Selectable temperature range 40 ° C ÷ 65 ° C, 10 ° C (antifreeze)
- Maximum thermal fuse temperature: 152 ° C
- Connecting cable: straight, gray color, length 1.2 m
If the heating rod is connected to the radiator for electric heating only, it is necessary to purchase a blanking plug for the second stand.
Products in series