RAMA LUX Bathroom Towel Radiator 651 W with Mirror 595x1448mm, graphite
Description
Properties
Brand | SAPHO | |
---|---|---|
Series | RAMA LUX | |
Size | 595x1448 mm | |
Width | 595 mm | |
Height | 1448 mm | |
Colour | Chrome | |
Material | Steel | |
Shape | Heating panels, Frame | |
Suggested el. heater | 600 W | |
Possibility of heating | Electric Heating, Combined heating - Electric/Central, Central heating | |
Spacing connection 50 mm | Asymmetric (Side) | |
Spacing connection | 50 mm | |
Output | 651 W | |
Equipment | Mirror | |
Weight / Piece | 17.25 kg | |
Packing | 1 Piece | |
Guarantee | 2 years |
Explanations
Electric heating
If the heater is only heated electrically, i.e. only a heating rod is used, a 1/2" radiator plug must be purchased additionaly. This serves to plug the other hole in the heater which would otherwise be used for the central heating connection valve. We recommend filling the heater with distilled water. It is also recommended to pour in the LIKIDO antifreeze and anti-corrosive heat transfer fluid.
It is necessary to use a heating rod with the same or similar performance according to the specification of the radiator. For heating rods with a thermostat, the temperature of the liquid in the heater is controlled.
Dual fuel heating
Dual fuel towel rails combine two types of heating - central and electric. They can be connected to the central heating system, and also to an electric socket. We recommend a heating rod with the same or similar performance according to the specification of the radiator.
If you have a heater with a central connection, in depends on whether the heating rod can be connected via a valve (in such case a combination valve is used) or whether the rod is connected separately to the side part of the radiator (using a conventional valve). In case of a side connection, a combination valve is always used. There is a choice of using a manual valve or a valve with a thermostatic head
Manual valve: the valve control head can be installed on the left/right side regardless of the hot water supply location. The temperatur eis controlled manually.
A valve with a thermostatic head: the integrated thermostat maintains the temperature inside the towel rail. The thermostatic head must be located at the hot water inlet (except MONO ONE).
The connection valves we offer are supplied with a clamping fitting for the most common pipes (Ø15 mm for copper and Ø16 mm for Alupex), so there is no need to buy anything else for the connection. For covering the inlet pipes and holes in the wall, we recommend the addition of cover rosettes.
Central heating
In the case of central heating, the selection of the connection valves is very important. You can choose between using a manual valve or a valve with a thermostatic head.
Manual valve: the valve control head can be installed on the left/right side regardless of the hot water supply location. The temperatur eis controlled manually.
A valve with a thermostatic head: the integrated thermostat maintains the temperature inside the towel rail. The thermostatic head must be located at the hot water inlet (except MONO ONE).
The connection valves we offer are supplied with a clamping fitting for the most common pipes (Ø15 mm for copper and Ø16 mm for Alupex), so there is no need to buy anything else for the connection. For covering the inlet pipes and holes in the wall, we recommend the addition of cover rosettes.
Description
If the radiator is heated only electrically, it is necessary to buy a ku “plug for the radiator (see accessories).
Series description
Modern and elegant radiator with mirror. Decorative radiator with very interesting design, representing modern trends. The heating element forms a mirror frame, fulfilling both the decorative and usable function and saving space. The radiator will be used not only in the bathroom, but also in other areas.
The body is supplied automatically with left valves connecting, ATP can be supplied with a right connection as ATYP.
Advantages:
- Modern design
- Universal use
- Possibility of combination of central and electric heating
Combination of central and electric heating
Electrical heating
Central heating
- Extended Warranty
Options for "central" connection of heating ladders
1. Central heating - manual valve
CUBE set COMPACT kit Copper fittings ALU couplings Covering rosettes
If you decide to buy a ladder of this type, you need to choose a suitable attachment kit.
If the heating is to be used only for hot water heating without a thermostatic head, it is necessary to purchase the connection kit
eg COMPACT or CUBE (according to heating design).
CUBE is available in chrome, stainless steel or silver.
The COMPACT kit is available in chrome only. For COMPACT and CUBE, the right / left variant is not distinguishable.
ADVICE! Tail pipe openings are not always perfectly executed, so we recommend buying a set of cover markers. Covering rosettes are used to cover Cu or Alupex pipes and unclean openings in the wall. Covering rosettes are available in chrome or stainless steel.
ATTENTION! Our design valves have a special thread 24-19, so it is necessary to purchase the recommended fitting for each valve according to the material and diameter of the pipe - copper / alupex.
Clamps are available in chrome or stainless steel.
2. Central heating - valve with thermostatic head
TWIN connection Copper fittings ALU coupling Covering rosette
If you decide on the thermostatic variant, we recommend the TWIN design :
The TWIN set is available in chrome or stainless steel.
ADVICE! The TWIN set is available in right / left variant. The figure above shows the left option. This means that the hot water supply is to the left, as well as the thermostat itself is pointing to the left (always at the front view). We recommend selecting the valve so that the head always faces in the direction of the horizontal profiles of the heater and not on the opposite side.
ATTENTION! The already mentioned clamping fitting for heating assembling + cover rosette.
Available color variation of clamping fittings - chrome or brushed stainless steel.
3. Combined heating - valve with thermostatic head
Heating rod Copper fittings ALU coupling Covering rosette
If you decide to use the heater for both hot-water and electric heating, we recommend the TWIN COMBI connection set + heating rod :
ATTENTION! Again, choose the right version of the left / right side, see the information above.
The TWIN COMBI is available in chrome or stainless steel.
ATTENTION! Clamping fitting + cover rosette.
Available color variation of clamping fittings - chrome or brushed stainless steel. Covering rosettes are available in chrome or stainless steel.
ADVICE! The heating rod can be retrofitted but this option is not recommended due to the likelihood of dismantling the heating ladder and releasing the heating circuit. To select the heating rod, refer to variant 4.
Available color version of chrome fitting or stainless steel. Covering rosettes are available in chrome or stainless steel.
4. Electrical heating - with thermostatic heating rod
When choosing electric heating we offer a wide selection of heating rods - ONE, ONE-D, MOA, KTX, GV ...
ADVICE! The heating rod selects the client according to his own taste, design and performance!
ATTENTION! The heating rod must be of adequate power according to the specific radiator specification or the lowest possible.
If the heater is heated only electrically, it is necessary to fill the heater with an anti-corrosion freeze-free anti-corrosion fluid such as LIKIDO . It is also necessary to buy a ½ "radiator plug.